Promat Tunnel
Bormstraat 24 - 2830 Tisselt
Tel. : +32 (0)15 71 81 00
Fax : +32 (0)15 71 81 09


Full Scale Fire Tests > Conclusions
..............................................................................................................................................................................................................

Ordinary commodities can give heat release rates equal to those in tank fires
(max HRR = 223 MW !)
Max temperature = 1365°C, Dutch RWS (RijksWaterStaat) curve best simulated
Radiation levels exceed maximum for fire fighters
Walls require protection as well, HC curve best simulated
Fire spread occurred in all tests
Rocks started to spall
The PROMATECT® –T system perfectly resisted 4 high intensity fires
(maximum 223 MW and 1365°C) and protected the tunnel structure as predicted
 
   

A report containing the set-up of the tests, the recordings of the data and the interpretation of the results was issued by:

The report also contains a cd-rom with all the pictures and video’s of the set-up and the fire tests, as well as all the technical/scientifical papers.

Click here to order your free copy of this report.