• Post fixed with anchors
In existing tunnels, or new build tunnels in which it was decided to install the fire
protective layer afterwards, the post fixing system can be applied.
The boards are anchored to the concrete substrate in the thickness required to satisfy the fire protection requirements. The joints between the boards are just buttjointed
without the use of any mastic, joint filler whatsoever.
In case of a circular lining, PROMATECT® -T boards can be used. PROMATECT® -
T can be flexed into the radius of the tunnel, without the use of excessive force. The
flexibility is such that it can cope with regular tunnel radiuses, depending on the
thickness of the board. Consult Promat technical department for further details. |